Flexible fire-resistant cable
- Product Description
-
This standard is primarily based on GB/T 12706.1-2020, “Extruded Insulated Power Cables and Accessories for Rated Voltages from 1 kV (Um = 1.2 kV) to 35 kV (Um = 40.5 kV)—Part 1: Cables for Rated Voltages of 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 kV),” as well as GB/T 19666-2019, “General Requirements for Flame‑Retardant and Fire‑Resistant Wires and Cables,” among other relevant standards. This product is intended for critical electrical engineering applications, including hazardous areas such as airports, oil depots, liquefied gas stations, chemical plants, coal mines, (nuclear) power stations, steel mills, and shipbuilding facilities; advanced and vital public infrastructure, such as satellite earth stations, railway wiring systems, alarm and fire‑protection systems; and environments where the safety of persons and property must be ensured, including historic buildings, hotels and guesthouses, high‑rise structures, museums, libraries, banks, hospitals, insurance institutions, shopping malls, and research institutes.
Product Model and Naming
Model number Name YTTW Copper-conductor, corrugated copper‑sheathed, inorganic mineral‑insulated flexible fire‑resistant cable YTTWV Copper‑core, corrugated copper‑sheathed, inorganic mineral‑insulated, PVC‑sheathed flexible fire‑resistant cable YTTWY Copper‑core, corrugated copper‑sheathed, inorganic mineral‑insulated, polyolefin‑coated, corrosion‑resistant outer sheath, flexible fire‑resistant cable. Product Specifications
Model number Rated voltage Number of cores Nominal Cross-Sectional Area/mm² YTTW
YTTWV
YTTWY450/750V
0.6/1kV1 1.0~630 2 1.0~300 3 1.0~240 4 1.0~185 3+1 3×16+1×10 3×25+1×16 3×35+1×16 3×50+1×25 3×70+1×35 3×95+1×50 3×120+1×70 3×150+1×70 3×185+1×95 3×240+1×120 3+2 3×25+2×16 3×35+2×16 3×50+2×25 3×70+2×35 4+1 4×16+1×10 4×25+1×16 4×35+1×16 4×50+1×25 4×70+1×35 5-7 1.0~4.0 12-37 1.0-2.5 Nominal thickness of the copper sheath
Nominal cross-sectional area/mm² Nominal thickness of copper sheath / mm 1 core 2-core 3-core 4 cells 5-core 7-core 12-core 19-core 24 cores 30-pin 37 cores 1.0 0.4 0.4 0.4 0.4 0.45 0.45 0.4 0.4 0.4 0.4 0.4 1.5 0.4 0.4 0.4 0.4 0.45 0.45 0.4 0.4 0.4 0.4 0.4 2.5 0.4 0.4 0.4 0.4 0.45 0.45 0.4 0.4 0.4 0.4 0.4 4 0.4 0.4 0.4 0.4 0.45 0.45 / / / / / 6 0.4 0.4 0.4 0.4 0.45 0.45 / / / / / 10 0.4 0.45 0.45 0.45 0.5 0.5 / / / / / 16 0.4 0.45 0.45 0.5 0.5 / / / / / / 25 0.4 0.5 0.5 0.5 0.5 / / / / / / 35 0.45 0.5 0.5 0.5 0.5 / / / / / / 50 0.5 0.5 0.5 0.6 0.6 / / / / / / 70 0.5 0.5 0.6 0.6 0.6 / / / / / / 95 0.5 0.5 0.6 0.6 0.6 / / / / / / 120 0.5 0.5 0.6 0.6 0.6 / / / / / / 150 0.5 0.6 0.6 0.7 0.7 / / / / / / 185 0.5 0.6 0.6 0.7 0.7 / / / / / / 240 0.6 0.6 0.6 0.7 0.7 / / / / / / 300 0.6 / / / / / / / / / / 400 0.6 / / / / / / / / / / 500 0.6 / / / / / / / / / / 630 0.6 / / / / / / / / / / Note: For conductor sizes not listed, the nominal thickness of the copper sheath shall be taken as the value closest to that specified for the corresponding conductor size.